Customization: | Available |
---|---|
After-sales Service: | 24*7 Available |
Warranty: | 5years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Data Sheet | |||
Model | ZXB05-SPM-302G-PAK | ZXB05-SPM-602G-PAK | ZXB05-SPM-802G-PAK |
Battery Input Data | |||
Battery Type | Lead-acid or Li-lon | ||
Battery Voltage Range(V) | 20-30 | 40-60 | |
Max.Charging Current(A) | 140 | 135 | 190 |
Max.Discharging Current(A) | 140 | 135 | 190 |
Charging Curve | 3 Stages/Equalization | ||
External Temperature Sensor | Optional | ||
Charging Strategy forLi-lon Battery | Self-adaption to BMS | ||
PVString Input Data | |||
Max.DC Input Power(W) | 3900 7800 10400 | ||
PV Input Voltage(V) | 370V(125V-500V) | ||
MPPT Range(V) | 150-425V | ||
Full Load DCVoltage Range | 300-425V | ||
Start-up Voltage(V) | 125V | ||
PV Input Current(A) | 13 | 18+18 | 26+26 |
Max.PV Isc(A) | 17 | 27+27 | 34+34 |
No.of MPPT Trackers | 1 | 2 | 2 |
No.of Strings Per MPPT Tracker | 1 | 1+1 | 2+2 |
AC Input/Output Data | |||
Rated AC Output and UPS Power(W) | 3000 | 6000 | 8000 |
Max.AC Output Power(W) | 3300 | 6600 | 8800 |
Peak Power(off grid) | 2 times of rated power,10S | ||
ACinput/Output Rated Current(A) | 13.6/13 | 27.3/26.1 | 36.4/34.8 |
Max.AC Input/Output Current(A) | 15/14.3 | 30/28.7 | 40/38.3 |
Max.Continuous AC Passthrough(A) | 35 | 40 | 50 |
Power Factor | 0.8 leading to 0.8 lagging | ||
Output Frequency and Voltage | 50/60Hz;220/230Vac | ||
Grid Type | Single Phase | ||
Total Harmonic Distortion(THD) | <3%(of nominal power) | ||
DC current injection | <0.5%In | ||
Efficiency | |||
Max.Efficiency | 97.60% | ||
Euro Efficiency | 96.50% | ||
MPPT Efficiency | >99% | ||
Protection | |||
PVArc Fault Detection | Integrated | ||
PV Input Lightning Protection | Integrated | ||
Anti-islanding Protection | Integrated | ||
PV String Input Reverse Polarity Protection | Integrated | ||
Insulation Resistor Detection | Integrated | ||
Residual CurrentMonitoring Unit | Integrated | ||
Output Over Current Protection | Integrated | ||
Output Shorted Protection | Intearatod | ||
Surge Protection | DC Type ll/AC Type II | ||
Over Voltage Category | DC Typell/AC Type III | ||
Certifications and Standards | |||
Grid Regulation | IEC61727/62116,EN50549-1 | ||
EMC/Safety Regulation | IEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN 62109-2 | ||
General Data | |||
Operating Temperature Range(ºC) | 40-60ºC>45ºC Derating | ||
Cooling | Smart cooling | ||
Noise(dB) | <50dB | ||
Communication with BMS | RS485;CAN | ||
Monitoring mode | wi-Fi+APP | ||
Weight(kg) | 19 | 19 | / |
Cabinet size(mm) (Excluding connectors and brackets) |
346W×416H×250D (Excluding connectors and brackets) |
346W×416H×250D (Excluding connectors and brackets) |
/ |
Cabinetsize(mm) | Ip65 | ||
Installation Style | Wall-mounted | ||
Warranty | 5 Years |
Data Sheet | ||
Model | ZXB01-SPM-103G-EU | ZXB01-SPM-123G-EU |
Battery Input Date | ||
Battery Type | Lead-acid or Li-lon | |
BatteryVoltage Range(V) | 40-60 | |
Max.Charging Current(A) | 220 | 250 |
Max.Discharging Current(A) | 220 | 250 |
Charging Curve | 3.Stages /Equalization | |
External Temperature Sensor | yes | |
Charging Strategy for Li-lon Battery | Self-adaption to BMS | |
PVString Input Data | ||
Max.DC Input Power(W) | 13000 | 15600 |
PV Input Voltage(V) | 370V(125V~500V) | |
MPPT Range(V) | 150~425V | |
Full Load DC Voltage Range | 200~425V | |
Start-up Voltage(V) | 125V | |
PV Input Current(A) | 26+26+26 | 26+26+26 |
No.of MPPTTrackers | 3 | 3 |
No.ofStrings Per MPPT Tracker | 1+1+1 | 1+1+1 |
ACInput/Output Data | ||
Rated AC Output and UPS Power(W) | 10000 | 12000 |
Max.AC Output Power(W) | 11000 | 13200 |
Peak Power(o ffgrid) | 2 times of rated power,10 S | |
AC input/Output Rated Current(A) | 45.5/43.5 | 54.6/52.2 |
Max.AC Input/Output Current(A) | 50/47.9 | 60/57.4 |
Max.Continuous AC Passthrough(A) | 60 | 60 |
Power Factor | 0.8 leading -0.8 lagging | |
Output Frequency and Voltage | 50/60Hz;220/230Vac | |
Grid Type | Single Phase | |
Total Harmonic Distortion(THD) | <3%(of nominal power) | |
DC current injection | <0.5%In | |
Efficiency | ||
Max.Efficiency | 97.60% | |
Euro Efficiency | 96.50% | |
MPPT Efficiency | >99% | |
Protection | ||
PV Arc Fault Detection | Integrated | |
PV Input Lightning Protection | Integrated | |
Anti-islanding Protection | Integrated | |
PV String Input Reverse Polarity Protection | Integrated | |
InsulationResistor Detection | Integrated | |
Residual Current Monitoring Unit | Integrated | |
Output Over Current Protection | Integrated | |
Output Shorted Protection | Integrated | |
Over Voltage Category | Integrated | |
Surge Protection | DC Type ll/AC Type Il | |
Over Voltage Category | DC Type ll/AC Type III | |
Certifications and Standards | ||
Grid Regulation | IEC61727/IEC 62116,EN 50549-1 | |
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN 62109-2 | |
General Data | ||
Operating Temperature Range(ºC) | -40~60ºC,>45ºC Derating | |
Cooling | Smart cooling | |
Noise(dB) | <50 dB | |
Communication with BMS | Rs485;CAN | |
Monitoring mode | WIFI,APP | |
Weight(kg) | 31 | |
Cabinet size(mm) | 446W×576H×254D(Excluding connectors and brackets) | |
Protection Degree | IP65 | |
Installation Style | Wall-mounted | |
Warranty | 5 Years(10 Years Optional) |